CardioPro
System

What
Is It:
Measurements of Heart Rate Variability (HRV) are a reliable
reflection of the many physiological factors modulating the normal
rhythm of the heart. In fact, they provide a powerful means
of observing the interplay between the sympathetic and
parasympathetic nervous systems.
A growing number of studies indicate that increased variability in
the heart's interbeat interval is physiologically desirable.
CardioPro is a specialized biofeedback application that provides a
sophisticated array of feedback tools for monitoring HRV and Respiratory
Sinus Arrhythmia (RSA); it is an effective adjunct to any relaxation and
self-regulation training program.

Real-time audio and visual feedback on the standard deviation of the
IBI provides an immediate indication of changes in heart rate
variability.
A programmable respiration pacer allows the user to define breathing
cycles that include inspiration and expiration time as well as breath
holding pauses.
The Statistical Report printout of standard calculations includes
power analysis for the LF, HF and VLF components of the HRV spectrum,
SDNN, NN50 and PNN50.
CardioPro's export function for the IBI data ensures compatibility
with third-party data analysis software packages.
A true 32-bit Windows™ application, CardioPro offers the best
combination of user-friendly graphical interface and powerful features
to make it the most competitive software package available for
respiration, RSA/HRV biofeedback and research.

System overview
Cardiopro is a specialized biofeedback application that focuses on
the physiology of the cardiovascular and respiratory systems. It
functions with the ProComp+ device and takes input from one EKG
(electrocardiograph), two respiration and, optionally, one temperature
and one BVP (blood volume pulse) sensor.
Basic functionality can be obtained with one EKG and one respiration
sensor; however, a second respiration sensor is necessary to work with
feedback on the thoracic/abdominal ratio. The Temp and BVP sensors are
used to provide peripheral information; they are not essential for the
respiration sinus arrhythmia (RSA) or heart rate variability (HRV)
functionality. With the EKG sensor, it is important to stress the
necessity for good skin preparation, particularly for dry or hairy
areas, before applying the electrodes. Using extra electrode gel, even
on pre-gelled electrodes ensures the best signal possible.
The simple graphic user interface easily leads the user through the
various steps of recording, reviewing and analyzing data. While
recording, the user can switch between three different monitoring
screens; each designed for a specific type of feedback. When a session
has been recorded, the user can replay or rescan it from the HRV display
screen.
The 3D spectral display is based on a 5 minute moving window of
inter-beat interval (IBI) data. This enables it to accurately display
the very low frequencies (VLF) right down to 0.003Hz (looking at this
end of the frequency range is essential to a number of clinicians). The
3D spectral display can be used in real-time while recording or after a
session, while reviewing data.
The RSA and 3D screens have a variable respiration pacer with
independent settings for in, out and hold phases.
Cardiopro provides both auditory and visual biofeedback for any one
of three physiological changes: Standard Deviation of the IBI (SDRR),
Heart Rate Max minus Heart Rate Min, and Thoracic / Abdominal ratio. The
available auditory feedback options include threshold-triggered
proportional or inverse-proportional MIDI tones.

State of the art data reviewing, editing, analyzing, printing and
exporting functions are provided in the review screens.
Uses industry standard* calculations and data format for raw and
normalized data. *(These are calculated as recommended in the Special
Report on Heart Rate Variability Standards of Measurement,
Physiological Interpretation and Clinical Use. Task Force of the
European Society of Cardiology and the North American Society of
Pacing and Electrophysiology)
32-bit Windows™ 95/98 environment, with graphic user interface
that’s simple and intuitive to use.
Functional ability to display EKG, 2 respiration, BVP and temp
modalities simultaneously, for time saving therapy and monitoring.
Three-trace line graph, for 2 channels of respiration* and a channel
of heart rate for RSA training. *(Powerful visual aid to train
abdominal breathing.)
Fully configurable breathing pacer including in / out and hold
phases to give accurate breathing management.
Very powerful self-contained IBI editing suite to remove ectopic
beats and other irregularities. Includes add, split and average
functions, all colour-coded for ease of use during high speed editing.
An IBI Tachogram, showing the Inter Beat Interval values for the
session gives a great overview of a session as a whole.
Time synchronized graph cursors give the ability to zero in on
specific areas of the EKG trace for closer inspection.
In addition to the wealth of visual feedback, there are three modes
of audio feedback for behavioral training.
- Abdominal breathing (Thor./Abd. Ratio).
- Respiratory Sinus Arrhythmia (HR Max- HR Min).
- Heart Rate Variability (SDRR).
Full colour 2 & 3D frequency analysis* in real time and review
modes. *(FFT (Fast Fourier Transform) frequency power spectrum of the
Inter Beat Intervals (IBI) in the 0.0033 - 0.4Hz bandwidth) It shows
Very Low Freq, Low Freq. & High Frequency information.
Developed in consultation with some of the leading experts in the
field of heart rate variability and RSA: Paul Lehrer Ph.D., Rob Nolan
Ph.D. and Richard Gervirtz Ph.D.
The system includes a database, for keeping relevant client
information and all session data in order and at-hand when needed.
Informative Printed Reports, with selectable data ranges to prevent
filling up your patient record room.
Export function for the raw or normalized IBI data - an invaluable
function for any researcher.
Uses Thought Technology’s reliable and world-renowned ProComp+
hardware as the patient interface.
Price Information
Order
Secure Now!
|